Reed relays
consist of a reed switch and coil fitted into a house, which could be plastic,
metal or moulded. Compared with
elecro-mechanical
relays, reed relays generally have a faster response time, lower coil
consumption and are smaller in size.
Furthermore, the switch
is sealed in a dry, inert atmosphere preventing the ingress of contaminants.
Operation
High
voltage Relays have outstanding performance in insulation and stand-off
voltage. Energizing the coil operates a reed
switch causing the
contacts to open or close. It is important that the switch is not overloaded
by applying loads in excess
of he switch ratings.
For details on switch loads refer to the reed relay specifications and the
reed switch application page
in this catalogue.
Vibration and Shock Resistance
During
the evaluation of vibration and shock resistance, the relays are driven with
nominal voltage. Te switches should not
open longer than 10 µsec.
|
|
Normally Open |
Change Over |
Wetted |
|
Vibration Resist. |
20g/ 5...2000 Hz |
10g/5...500 Hz |
10g/10...500 Hz |
|
Shcok Resistance |
100 g / 11 MS
Sine half wave |
50 g /11 ms
Sine half wave |
30 g / 11 ms
Sine half wave |
Washability
Resistance a Caltron,
Frean, alcohol and distilled (pure) water. During the final rinsing phase only
the purest substances
should be used.
Pull-in and Drop-out Voltage, Coil Resistance
The tolerances indicated are valid at
25°C +/- 3°C. The temperature coefficient of the coil resistance is 0.4 % /
°C.
Switching Voltage, Current and Capacity.
The parameters as listed for
switching voltage, current and capacity are maximum values. Exceeding any one
of these
values causes overload and reduces relay
life expectancy.
Contact Resistance
The contact resistance indicated is valid
for new relays at nominal coil voltage. The four-point method at 2VDC / 100mA
or
10 mA is applied. Custom solutions for special
applications, especially for switching signals smaller then 1 mV at 10µA (low
level -application) or applications requiring
dynamic contact resistance measurement can be produced for special
switching
needs.
General Parameters
Life Expectancy
The life expectancy of a Reed Relay
is at lease 10 5th ... 10 6th operations at nominal load. At minimum
load the life expectancy
can be up to 5 x 10 8th operations. The
mechanical life expectancy is 10 9th operations (min). Through the switchin of
higher
loads, especially inductive or capacitive
and lamp loads, life expectancy can be considerably rediuced due to exceeding
the
permissible maximum current.
Thermal Resistance of the DIL-SIl Reed Relays : 40
K/W.
Thermoelectric voltage : between FeNi (reed Switch) abd Cu(PCB) a
thermoelectric voltage U th = k x (T1 - T2) occurs with
the constant k = 50 £V /
°C(T=temperature).
Capacitance : The capacitance parameters are regarded as typical and are
calculated for versions without shielding.
Solderability : All relays meet the DIN8505 requirements. Hole diameter in
PCB : 0.65 mm
Temperatur range : The operating temperature of the relay is the
equivalent of the internatl temperature. If the relays are
used in ambient termperatures higher than
20 °C the max permissible operating voltage must be calculated accoring to
the
table indicated below, useing the formula
: UT = Umax x k 1
Switching Time : When using dry Reed Switches in realys, contact bounce
may occur. Pull in time type. 0.5...1.8 ms at
nominal voltage and 20 HZ. Drop out time (with
diode) typ. 0.5...1.5 ms at nominal voltage and 20 Hz.
Magnetic Shieldings : Magnetic shielding for Reed Relays are also
availabel :
- magnetic shielding for SIL Reed Relays
- top side and side by side
- top side and fornt end
- top side , side by side and front end
- magnetic shieldings for DIL-Reed relays
- top side, side by side and front end suitable for the DIL-high profile
Comment : Relays versions with 15 V nominal coil voltage are
available for orders exceeding min quantity of 1000 pieces.
Linecards :
Dry Reed Relays
Mercury
Wetted Reed Relays
High
Voltage Reed Relays
High